| Recommended FOUNDATION™ fieldbus Accessories |
Yokogawa confirms integration of third-party FOUNDATION™ fieldbus accessories such as power supplies, safety barriers, and arrestors etc., with the Yokogawa host system. Yokogawa has made a list of recommended FOUNDATION fieldbus accessories which have passed the integration test.
|
 |
 |
 |
| Pepperl+Fuchs |
FOUNDATION™ fieldbus Products for Yokogawa |
| |
KFD2-EB.R4A.B |
Redundant Power Feed Module |
|
KLD2-PC-1.1.IEC |
Conditioner |
|
KLD2-PR-1.IEC |
Isolated Fieldbus Power Supply/Repeater 24V, 400mA |
|
KLD2-STR-1.24.400.IEC
(Sales Termination) |
Standard fieldbus power supply, 400 mA |
|
KLD2-FBPS-1.25.360 |
Single Segment Fieldbus Power Supply 25-27V, 360mA output |
|
MB-FB-4.YO |
Yokogawa Motherboard with compatible ALF111 connector to suit cable No. AKB336
4x simplex Fieldbus segments (4x Power Supplies + 1x Diagnostic module) |
|
MB-FB-4R.YO |
Yokogawa Motherboard with 2x compatible ALF111 connectors to suit cable No. AKB336
4x redundant Fieldbus segments (8x Power Supplies + 1x Diagnostic module) |
|
MBHD-FB-4R.YO |
Power Hub Yokogawa Motherboard High-density with 2x compatible ALF111 connectors to suit cable No. AKB336
4x redundant Fieldbus segments (8x Power Supplies + 1x Diagnostic module) |
|
HD2-FBPS-1.25.360 |
Power Hub isolated Fieldbus Power Supply, 25- 27 V, 360 mA output |
|
HD2-FBPS-1.500 |
Isolated Fieldbus Power Supply, 28 - 30 V, 500 mA output |
|
HD2-FBPS-1.23.500 |
Isolated Fieldbus Power Supply, 21 - 23 V, 500 mA output |
|
HD2-FBPS-1.17.500 |
Isolated Fieldbus Power Supply for FNICO installations, 15 - 17 V, 500 mA output |
|
HD2-FBCL-1.500 |
Fieldbus Power Conditioner, 500 mA output |
|
HD2-DM-B |
Common Basic Fieldbus Diagnostic module to suit all motherboards and modules |
|
HD2-DM-A |
Advanced Fieldbus Diagnostic module to suit all motherboards and modules, compatible PRM ver R3.02.01 and higher |
| MTL |
|
MTL5995 |
|
| Relcom |
| |
FPS-I |
Redundant Power Supply |
| |
F880 |
F880:8-segment redundant fieldbus power supply system
F801:8-segment power conditioner module, 21.5 - 24.0V, 350mA output.
F880-CA:Module carrier, unpopulated, 8 x redundant segments, Yokogawa version, with system connectors for AKB336 cables, accepts 2 x 8-segment power conditioner modules. |
| HAWKE |
|
Route-Master Series100 |
IS Power Supply for Fieldbus |
| STAHL |
|
9412/PS-I |
Fieldbus Power Supply, redundant, Ex nA; with terminator |
|
 |
| |
KLD2-PR-Ex1.IEC1 |
Isolated fieldbus power supply FISCO |
|
KLD2-PR-Ex1.IEC |
Isolated fieldbus power supply FISCO |
|
F2D0-FB-Ex4.CGB |
Isolated Fieldbus Barrier with integrated short circuit protection |
|
RD0-FB-Ex4 |
Fieldbarrier for connecting to either and/or FISCO and Entity approved field devices mounted up to Zone 0, 4 spur version |
| MTL |
|
MTL5053 |
Exi Type |
| |
9311-FB Series |
Fieldbus Barrier, Ex e trunk/Ex i spurs for Zone 1 installation |
| STAHL |
|
9411/21 series |
Field Device Coupler Ex e/Ex i for Zone 1 installation |
|
| MTL |
| |
FP32 |
Panel Mount |
| |
TP32 |
Instrument Protection |
|
 |
 |
 |
| Pepperl+Fuchs |
FOUNDATION™ Fieldbus Products for Yokogawa |
| |
R-JBSC-4
(Replaced by R2-*versions) |
Short circuit protected spurs. 4 spur versions |
|
R-JBSC-6
(Replaced by R2-*versions) |
Short circuit protected spurs. 6 spur versions |
|
R-JBSC-8
(Replaced by R2-*versions) |
Short circuit protected spurs. 8 spur versions |
|
R-SP-E12 |
Segment Protector in ignition protection class EEx mb for use in category 2G (Zone 1), 12 spur version |
|
R-SP-N12
(Replaced by R2-*versions) |
Segment Protector in ignition protection class EEx nA[L] for use in category 3G (Zone 2) |
|
R2-SP-N4 |
Segment Protector in ignition protection class EEx nA[L] for use in category 3G (Zone 2), 4 spur version |
|
R2-SP-N6 |
Segment Protector in ignition protection class EEx nA[L] for use in category 3G (Zone 2), 6 spur version |
|
R2-SP-N8 |
Segment Protector in ignition protection class EEx nA[L] for use in category 3G (Zone 2), 8 spur version |
|
R2-SP-N10 |
Segment Protector in ignition protection class EEx nA[L] for use in category 3G (Zone 2), 10 spur version |
|
R2-SP-N12 |
Segment Protector in ignition protection class EEx nA[L] for use in category 3G (Zone 2), 12 spur version |
| Relcom |
|
FCS-MB8-SG |
8 device connection Megablock with integrated Short Circuit protection |
|
 |
| TURCK |
|
| |
JBBS-49-T415B/Ex |
FOUNDATION fieldbus IP67 junction box, 4-channel |
|
JBBS-49-T615B/Ex |
FOUNDATION fieldbus IP67 junction box, 6-channel |
|
JBBS-49SC-T414/Ex |
FOUNDATION fieldbus IP67 junction box, 4-channel.
(With Spur line short-circuit protection, nickel-plated brass) |
|
JBBS-49SC-T415B/Ex |
FOUNDATION fieldbus IP67 junction box, 4-channel.
(With Spur line short-circuit protection) |
|
JBBS-49SC-T615B/Ex |
FOUNDATION fieldbus IP67 junction box, 6-channel.
(With Spur line short-circuit protection) |
|
| MOORE-HAWKE |
| |
TG200 Series
(For non-incendive
device in Zone2) |
TG2*4 : 4device wiring hub, with automatic terminator
TG2*8 : 8device wiring hub, with automatic terminator
TG2*X : 10device wiring hub, with automatic terminator |
|
|
|
|
|
 where people are watchful and attentive |
|
|
|
|
|