AV550G Zirconia Oxygen Averaging Converter
Model AV550G
Zirconia Oxygen Averaging Converter


Zirconia Oxygen Analyzer Converter AV550G
Regulatory Compliance
A multiple point oxygen measurement system may be required for situations when gas stratification in the flue duct affects combustion control.

The AV550G Averaging Converter can accept inputs from up to eight zirconia oxygen detectors. It sends output signals for the individual as well as averages of multiple oxygen concentrations.
A robust multipoint converter reduces installation and maintenance costs.
 
A large 5.7-inch color LCD display shows various measurement, setup, calibration, and trend screens.
Its intuitive touch screen, is easy to read and makes set up and maintenance simple. Other standard features include new self-diagnostics and a hot swap function that allows a desired probe to be disconnected/reconnected for inspection or maintenance just by turning off the power of the relevant channel.
 
The AV550G Averaging Converter is ideal for combustion control in large utility boilers or various industrial furnaces.


   Bulletin 

   General Specification 

   User's Manual 
   User's Manual [HART] 
   User's Manual [Fieldbus] 
* Full color touch screen
* Special trend graph functions with customer graph configuration
* Multiple display modes shows average data, single detector or all detector gas concentrations
* Handles input of up to 8 oxygen detectors
* “Hot swap” of channel cards so the analyzer remains on line while maintenance is performed
* Eight 4-20mA outputs for individual detectors.
* Three 4-20mA outputs for average oxygen concentration outputs.
* Failed, in calibration, or alarming, detectors are automatically excluded from average calculations.
* Data of Hi and Low alarm can be excluded
* Allows contact input, calibration activation, range change and detector performance validation.
* Remote maintenance using digital communications (HART of FOUNDATION Fieldbus) reduces maintenance costs.
Note: HART is a registered trademark of HART Communication Foundation.
         FOUNDATION is a registered trademark of Fieldbus foundation.
Compatibility of Detectors ZR22G, ZO21D, ZO21DW
Number of Detectors

1 to 8
Expandable up to 8
Bases for 4CH and 8CH are available

Display 5.7 inches color LCD display of size 320 by 240 dot with touch screen
Output Signal 4 to 20 mA DC (maximum load resistance 550Ω)
Average-value Output; 3 points
Independent Output; Output to each channel
Communication HART, Fieldbus
Contact Output 5 points, contact capacity 30V DC 3A, 250V AC 3A (resistive load)
Contact Output for Individual Channel Fail Output to each channel
Normally energized.
Contact Input 2 points, voltage free contacts
Calibration Method; zero/span calibration
Calibration mode; autmatic, semi-automatic and manual (with an LCD touch screen)
Ambient Temperature -5 to +50℃
Humidity Range 10 to 85%RH (non-condensing)
Power Supply Voltage 100 / 115 V AC, 230V V AC
Construction Indoor installation
Installation Wall mounting
Paint Color Silver Gray (Munsell 3.2PB7.4/1.2)
Weight Approx. 13kg (100 V type), Approx. 25kg (200 V type)